12
Operation
Electric shock hazard:
Contact with live circuits could result in severe injury or death.
1. Refer to the Settings Table. Set the selector to the proper setting, press SELECT (when instructed to
do so), and connect the test leads to the meter.
2. Refer to “Typical Measurements” for specific measurement instructions.
3. Test the unit on a known functioning circuit or component.
•If the unit does not function as expected on a known functioning circuit, replace the battery and/
or fuses.
•If the unit still does not function as expected, call Greenlee for technical assistance
at 800-435-0786.
4. Take the reading from the circuit or component to be tested.
Settings Table
To measure this
characteristic …
Set the
selector to this
symbol…
These icons will
appear on the
display …
Connect
the red
lead to…
Connect
the black
lead to …
All Models
Voltage
(1000 V max)
and V
ΩV COM
and V
Resistance
Ω
and press
SELECT
MΩ
ΩV COM
Continuity*
and Ω
Diode
diod (momentarily)
and V
Voltage (600 mV max)**
mV
mV ΩV COM
Current (8A max)**
A mA
A, or
A COM
Current (600mA max)**
A mA
mA, or
mA µA COM
Current (6000µA max)**
µA
µA, or
mA µA COM
This table continues on the next page.
Comments to this Manuals