DM-200A • DM-210A • DM-510A
13
Operation (cont’d)
Settings Table (cont’d)
To measure this
characteristic …
Set the
selector to this
symbol…
These icons will
appear on the
display …
Connect
the red
lead to…
Connect
the black
lead to …
All Models (cont’d)
Frequency—Line Level
Voltage or Current
, A, mA, or µA
and press Hz
Hz ΩV COM
Frequency—Logic Level*** mV and press Hz Hz ΩV COM
EF
single probe†
Any voltage or
current function
and press EF for
at least 1 second
E.F.
ΩV —
EF
non-contact†
— —
DM-210A and DM-510A Only
Capacitance††
Ω
and press
SELECT
nF
Temp
ΩV
COM
Temperature Temp
C or F
(press SELECT to
change scale)
Temp
ΩV
COM
DM-510A Only
Auto select AC volts, DC volts,
resistance, and continuity (low
impedance measurement)
AutoCheck
and LoZ
Temp
ΩV
COM
* Tone indicates continuity. The threshold is between 10 Ω and 80 Ω.
** Press SELECT for AC or DC, as required.
*** Logic level frequency has a fixed sensitivity and is for digital signals. Refer to “Accuracy”.
† Refer to the “Using the Features” section for an explanation of EF (electric field detection).
†† Discharge capacitor before measurement. Discharge a large capacitor through an appropriate
resistive load.